Online UPS
TF-C Series Three Phase In - 3 Phase Out 10-30 kVA
TF-C Series are 3 phase input, 3 phase output, transformer-less parallel redundancy online UPS series, featured with smallest footprint cabinet, built-in batteries, DSP Control, Common Battery, Programmable battery voltage, intelligent charge mode with powerful battery charger, is an ideal budget-concerned solution to your server, bank, industrial equipment, internet data center, telecom, IT equipment and other Mission-critical application.
- IGBT Rectifier & Inverter
- DSP Digital Processor Technology
- High Frequency Double Conversion Technology
- Active Input Power Factor Correction (APFC)
- Wide Input Voltage Range
- High Output Power Factor
- Cold Start
- Automatic Frequency Detection
- 50/60 Hz Frequency Converter Mode
- Up to %98 High Efficiency (Eco Mode)
- Load Controlled Automatic Fan Control Speed
- Automatic Power On / Off by User Set Up to Load Capacity
- Selectable Battery Quantity 14/16/18/20
- Compact, Small Design
- LCD+LED Pane
- Energy Saving with Eco Mode
- Charges Batteries up to %90 Capacity in 4 hours by Quick Charge System
- Long Battery Life with Advanced Battery Management (ABM)
- Generator Compatible Operation
- Alarm Log Recording
- Standard Emergency Power Off (EPO)
- Standard Mechanical Bypass Switch
- Standard RS 232/USB Communication Ports
- RS 485/SNMP/AS400 Communication Ports (Optional)
- N+1, Up to 6 Unit Parallel Operation (Optional)
- Adding Extra Batteries for more Backup (Optional)
- Electromagnetic Compatibility
MODEL | TF-C-10 | TF-C-15 | TF-C-20 | TF-C-30 |
Apparent Power (kVA) | 10 | 15 | 20 | 30 |
Active Power (kW) | 9 | 13,5 | 18 | 27 |
INPUT | ||||
Voltage | 3P+N+GND; 360Vac/380Vac/400Vac/415Vac | |||
Voltage Tolerance | 277~485 Vac (<%50Load) | |||
190~277 Vac (%50-%100Load) | ||||
Frequency | 50 – 60Hz (Automatic Detect) | |||
Frequency Range | 40-70Hz±%0,5 | |||
Power Factor | ≥0,99 | |||
THDi | ≤%5 | |||
Bypass Voltage Tolerance | -%40 ~ +%15 Vac (Adjustable) | |||
OUTPUT | ||||
Voltage | 3P+N+GND; 360Vac/380Vac/400Vac/415Vac – Selectable from LCD | |||
Voltage Regulation | ±%1 | |||
Frequency | Online Mode: Sync with Mains; (45~55Hz) / Battery Mode: 50/60Hz ± 0,1 Hz | |||
Wave Form | Pure Sine Wave | |||
Crest Factor | 3:1 | |||
THDv | Lineer Load≤%2; Non Lineer Load≤%5 | |||
Transfer Time | Online Mode - Battery Mode:0 ms / Inverter - ByPass Mode: 0 ms | |||
Inverter Overload Capacity | 10 min@%102-%125 Load then ByPass | |||
1 min@%125-150 Load then ByPass | ||||
0,5 sec@>%150 Load then ByPass | ||||
ByPass Overload Capacity | 20min@%102-%125LoadthenShutDown | |||
2min@%125-150LoadthenShutDown | ||||
1sec@>%150LoadthenShutDown | ||||
BATTERY | ||||
Battery Voltage | 240 Vdc for Standart Models ; 168/192/216/240 Vdc (Optional) for Long Backup Models | |||
Battery Quantity/Capacity | 20*12V-9Ah | 40*12V-7Ah | 40*12V-9Ah | |
Battery Charge Time | 4 hrs for %90 Capacity at StandartModels; Up to Battery Capacity at Long Backup Models | |||
SYSTEM | ||||
Efficiency | Online Mod:≥%93 / Eco Mode %98 | |||
Panel | LCD+LED | |||
Alarms | Battery Mode, Low Battery, Fan Failure | |||
Parallel Working | Up to 6 Unit | |||
ENVIRONMENTAL | ||||
Operating Temperature | 0˚C-40˚C | |||
Relative Humidity | %20-%90 (Non Condensed) | |||
Audible Noise | ≤ 60 dBA (from 1 m.) | ≤65 dBA (from 1 m.) | ||
COMMUNICATION | ||||
Standart RS232 / Optional USB | Windows 98/2000/2003/XP/Vista/7/8 | |||
Optional SNMP | Power Management with SNMP ,Web Browser (Optional) | |||
STANDARDS | ||||
LVD&EMC | EN62040-1:2008 (LVD); EN62040-2:2006 (EMC) | |||
PHYSICAL | ||||
Net Dimensions (WxDxH )mm | 350*655*732 (Long Model) | |||
350*785*858 (Standart) | 350*785*1078 (Standart) | |||
Packaged Dimensions (WxDxH) mm | 472*780*920 (Long Model) | |||
472*910*1050 (Standart) | 472*910*1260 (Standart) | |||
Net Weight (kg) | 55(L), 115(St) | 60(L), 155(St) | 61(L), 175(St) | 65(L), 235(St) |
Gross Weight (kg) | 65(L), 125(St) | 70(L), 170(St) | 71(L), 190(St) | 75(L), 250(St) |
TF-C SERIES UPS
Download(222.35 KB)